HomeProductsSolenoid ValveTransmission solenoid valve271526710122 4/2 Pneumatic Valve

271526710122 4/2 Pneumatic Valve

  • $8
    ≥100
    Box
100 /Box (Min. Order)
Payment Type:
T/T,Paypal
Incoterm:
FOB
Min. Order:
100 Box
Transportation:
Ocean,Air,Express
Port:
NINGBO,SHANGHAI
Share:
  • Product Description
Overview
Product Attributes

Model No.271526710122

BrandMEIRUIER

Place Of OriginChina

WarrantyOne Year

Processing CustomNo

Encapsulation1

Product StatusBrand new

Voltage24V

Applicable Car ModelsTata

Part No/OE271526710122

Cross-border Export SupplyYes

Supply Ability & Additional Information

PackagingNORMAL

ProductivityA THOUSAND A DAY

TransportationOcean,Air,Express

Place of OriginWENZHOU

Supply AbilityPRODUCT HAVE MORE STOCK,CAN SHIP IN THE FIRST TIME

CertificateIATF16949

HS Code8708309500

PortNINGBO,SHANGHAI

Payment TypeT/T,Paypal

IncotermFOB

Packaging & Delivery
Selling Units:
Box
Package Type:
NORMAL
Picture Example:
  Share several common fault cases and solutions. Fault one: Solenoid valve coil short circuit or open circuit detection method: first use a multimeter to measure its on-off, the resistance value is close to zero or infinity, that indicates that the coil short circuit or open circuit. If the measurement of its resistance is normal (probably tens of ohms), it does not mean that the coil must be good (I once measured a Solenoid Valve coil resistance of about 50 ohms, but the solenoid valve can not operate, everything is normal after replacing the coil), please carry out the following final test: find a small screwdriver and place it near the metal rod worn in the solenoid valve coil, and then energize the solenoid valve, if it feels magnetic, then the solenoid valve coil is good, otherwise it is bad. Fault solution: replace the solenoid valve coil. Fault two: There is a problem with the solenoid valve plug/socket If the solenoid valve is the kind with a plug/socket, there may be a problem with the metal reed of the socket, a problem with the wiring on the plug (such as connecting the power cord to the grounding wire) and other reasons that cannot send the power to the coil. It is best to make a habit of screwing the fixing screw after inserting the plug into the socket, and screwing on the fixing nut on the coil after the spool stem. If the plug of the solenoid coil is equipped with a light-emitting diode power indicator, then the DC power supply must be connected when the solenoid valve is driven, otherwise the indicator will not light up. In addition, do not swap power plugs with light-emitting diode power indications of different voltage levels, as this will cause the LEDs to be burned out/the power supply (replace with a plug with a lower voltage level) to be short-circuited or the LEDs emit very weakly.

Product Categories : Solenoid Valve > Transmission solenoid valve

Email to this supplier
  • *Subject:
  • *To:
    Ms. Li
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

HomeProductsSolenoid ValveTransmission solenoid valve271526710122 4/2 Pneumatic Valve
Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send